Archive for December 17th, 2013
#lspci
01:00.0 Ethernet controller: Broadcom Corporation NetXtreme II BCM5709 Gigabit Ethernet (rev 20)
01:00.1 Ethernet controller: Broadcom Corporation NetXtreme II BCM5709 Gigabit Ethernet (rev 20)
02:00.0 Ethernet controller: Broadcom Corporation NetXtreme II BCM5709 Gigabit Ethernet (rev 20)
02:00.1 Ethernet controller: Broadcom Corporation NetXtreme II BCM5709 Gigabit Ethernet (rev 20)
03:00.0 RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2108 [Liberator] (rev 05)
08:03.0 VGA compatible controller: Matrox Electronics Systems Ltd. MGA G200eW WPCM450 (rev 0a)
#smartctl -d megaraid,0 -a /dev/sda
#smartctl -d megaraid,2 -a /dev/sda
#smartctl -d megaraid,3 -a /dev/sda
Vendor: SEAGATE
Product: ST3146855SS
Revision: 0002
User Capacity: 146,815,737,856 bytes [146 GB]
Logical block size: 512 bytes
Logical Unit id: 0×5000c50002fc27b3
Serial number: 3LN2T8WQ000098183TGT
Device type: disk
Transport protocol: SAS
Local Time is: Tue Dec 17 09:27:58 2013 ICT
Device supports SMART and is Enabled
Temperature Warning Enabled
SMART Health Status: OK
Current Drive Temperature: 37 C
Drive Trip Temperature: 68 C
———————-
google MegaCLI linux IBM Support download
;
#rpm -ivh Lib_Utils-1.00-09.noarch.rpm
#rpm -e srvadmin-storelib-sysfs
#rpm -ivh MegaCli-8.04.10-1.noarch.rpm
#cd /opt/MegaRAID/MegaCli/
———————
follow this script
#./megalsi.sh status
Adapter 0 — Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-5, Secondary-0, RAID Level Qualifier-3
Size : 272.25 GB
Parity Size : 136.125 GB
State : Optimal
Strip Size : 64 KB
Number Of Drives : 3
Span Depth : 1
—————-
# ./megalsi.sh drives
Slot Number: 0 - Online, Spun Up
Slot Number: 1 - Online, Spun Up
Slot Number: 2 - Online, Spun Up
Slot Number: 3 - Hotspare, Spun Up